Open vented system with two solid fuel appliances, two radiator zones and a domestic hot water (DHW) cylinder

Download PDF

System schematic of an open vented system with two solid fuel appliances, two radiator zones and a domestic hot water (DHW) cylinder.

The two solid fuel applainces use the DHW cylinder as a common DHW heat leak circuit.

The NRGZone 4 manifold ensures that the central heating zones and the DHW cylinder has access to the warmest possible water for their flow.